The SU6000RT4UHVG 6000VA/5400W on-line, double-conversion UPS system offers complete power protection for critical server, network and telecommunications equipment in a single 4U rack/tower compatible housing. Full-time active power conditioning provides clean, continuous dual-conversion AC output free of voltage fluctuations, power interruptions and line noise. Fault-tolerant auto-bypass prevents unexpected service interruptions during UPS overload or internal fault conditions. Detachable back panel PDU with manual bypass switch supports hot-swappable whole UPS replacement with no interruption to connected equipment. Single all-in-one rack / tower housing installs in only 4U with a maximum installed depth of only 20.7 inches (526 millimeters). Maintains full-time sine wave output within 2% of selectable 200/208/220/230/240V nominal during brownouts as low as 100V and overvoltages as high as 300V. Expandable runtime is supported with optional BP192V12-3U external battery packs. Battery independent restart ensures automatic UPS power-up without user interaction after lengthy power outages, even when batteries are expired and require replacement. Double-conversion operation converts raw input from AC to DC, then re-synthesizes output power back to perfect sine wave AC with enhanced protection from harmonic distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS types. Highly efficient operation in optional economy mode significantly reduces BTU heat output and operating energy costs. Network-grade AC surge and noise suppression. Supports detailed monitoring of equipment load levels, self-test data and utility power conditions via built-in RS-232 and USB interfaces. Optional network management card options available. HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and macOS. PowerAlert monitoring software offers detailed site power and UPS updates with support for safe auto-shutdown of connected systems as UPS batteries become depleted. Supports Emergency Power Off (EPO) via built-in interface. front-panel LEDs and LCD readout with scroll controls support front-panel visual monitoring of all major UPS for a variety of control options to support advanced UPS settings and configurations. LED / LCD display panel rotates for viewing in rack-mount or tower configurations. Hardwire input and four C19 outlets. Support for optional North American and International cordsets. External battery packs are field replaceable and hot swappable.

SU6000RT4UHVG 6000VA / 6kVA / 5400 watt on-line, double-conversion UPS system in a single 4U rack/tower compatible housing (output is limited to 4992 watts when used at 208V with L6-30P input plug)
Full-time active power conditioning maintains clean, continuous dual-conversion AC output free of voltage fluctuations, power interruptions and line noise
Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions
Detachable back panel PDU contains hardwire input line cord connection, output receptacles and manual bypass switch to support hot-swappable whole UPS replacement with no interruption to connected equipment
Hardwire input and 4 C19 output receptacles
Included rail kit supports 4U 19-inch rack-mount installation in 4-post racks
Optional 2POSTRMKITHD supports installation in 2-post 19-inch racks (1 required for SU6000RT4UHVG)
Optional 2-9USTAND supports upright tower placement (1 required for SU6000RT4UHVG)
Maximum installed rack depth of only 20.7 in. / 52.6cm
Maintains full-time sine wave output within 2% of selected 200/208/220/230/240V nominal in double conversion mode
Corrects brownouts to 156V at full load (100V at 50% load or less)
Corrects overvoltages to 290V at full load (300V at 90% load or less)
Supports 50/60 Hz operation for worldwide frequency compatibility
Double-conversion operation offers full-time AC to DC, then DC to AC conversion to maintain perfectly regulated sine wave AC output with enhanced protection from harmonic distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS types
High efficiency ECONOMY MODE operation significantly reduces BTU heat output and operating energy costs
Network-grade AC surge and noise suppression
Supports detailed monitoring of equipment load levels, self-test data and utility power conditions via built-in RS-232, USB and network management card options
Compatible with UPS management card options TLNETCARD, WEBCARDLX, SNMPWEBCARD, MODBUSCARD and RELAYIOCARD
Optional WEBCARDLX (sold separately) with the latest version of PowerAlert Device Manager firmware (PADM20) provides enhanced remote management capabilities
PADM20 and PowerAlert Element Manager (PAEM) form a powerful tool for expanding maintenance functions in large installations, including firmware update checks and backup and restoration of device configurations
Optional RELAYIOMINI interface module offers three configurable hard contact closure outputs for custom event notification (requires removal of USB interface module)
HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and macOS
USB & Serial ports enable data-saving unattended shutdown when used with PowerAlert software, available via FREE download from tripplite.eaton.com/products/power-alert
Front panel LEDs and LCD readout with scroll controls support front-panel visual monitoring of all major UPS functions with support for a variety of control options to support advanced UPS settings and configurations
LED/LCD display panel rotates for viewing in rack-mount or tower configurations
Supports Emergency Power Off (EPO) via built-in interface
Battery independent restart ensures automatic UPS power-up without user interaction after lengthy power outages, even when batteries are expired and require replacement
BP192V12-3U external battery packs are field replaceable and hot swappable
Intelligent battery management system with temperature-compensated charging extends battery life
Some external battery configurations require the use of External Battery Configuration Software (see manual)
Frequency conversion mode enables conversion of 60 Hz to 50Hz or 50Hz to 60 Hz (no de-rating)

Specifications

Power
Output power5400 W
Input operation voltage (min)200 V
Input operation voltage (max)240 V
Output operation voltage (min)208 V
Output operation voltage (max)240 V
Maximum current40 A
Efficiency96%
Emergency Power Off (EPO)Yes
Power factor0.9
Crest factor3:1
Output power capacity6 kVA
Ports & interfaces
Cable length3 m
AC outlets quantity4 AC outlet(s)
AC outlet typesC19 coupler
USB 2.0 ports quantity1
Serial ports quantity1
RS-232 ports1
Performance
Number of phases1
LED indicatorsYes
EMI/RFI noise filteringYes
Noise level60 dB
Audible alarm(s)Yes
Features
Country of originChina
Output power5400 W
Input operation voltage (min)200 V
Input operation voltage (max)240 V
Output operation voltage (min)208 V
Output operation voltage (max)240 V
Maximum current40 A
Efficiency96%
EMI/RFI noise filteringYes
Emergency Power Off (EPO)Yes
Power factor0.9
Noise level60 dB
Crest factor3:1
Audible alarm(s)Yes
Output power capacity6 kVA
Input frequency50/60 Hz
Battery
Battery recharge time6 h
Typical backup time at half load8.5 min
Typical backup time at full load2 min
Hot-swap batteryYes
Design
Country of originChina
Form factorRackmount
LED indicatorsYes
Product colourBlack
CertificationUL1778 CSA FCC Part 15 Category A IEC 61000-4-5 1995 B
Cable length3 m
Rack capacity4U
Display typeLED
Operational conditions
Operating temperature (T-T)0 - 40 °C
Storage temperature (T-T)-15 - 50 °C
Operating altitude0 - 3000 m
Technical details
Sustainability certificatesRoHS
Weight & dimensions
Package width863.6 mm
Package depth609.6 mm
Package height762 mm
Weight49 kg
Width445 mm
Package weight86.2 kg
Height174 mm
Depth526 mm
Packaging data
Package width863.6 mm
Package depth609.6 mm
Package height762 mm
Package weight86.2 kg
Logistics data
Products per master (outer) case1 pc(s)
Master (outer) case width863.6 mm
Master (outer) case length609.6 mm
Master (outer) case height762 mm
Master (outer) case gross weight86.2 kg
Master (outer) case GTIN (EAN/UPC)00037332157232
Certificates
CertificationUL1778 CSA FCC Part 15 Category A IEC 61000-4-5 1995 B
Other features
Number of phases1
Input connection typeL6-30P
Relative humidity0 - 95%
Management platformSNMP