Tripp Lite PDUMH32HVAT 7.7kW Single-Phase 200-240V Local Metered Automatic Transfer Switch PDU, 2 IEC309 32A Blue Inputs, 16 C13, 2 C19 Outlets, 2U, TAA
- Brand: Tripp Lite
- Category:
- SKU: PDUMH32HVAT
- EAN: 0037332186881
7.7kW Single-Phase 200-240V Local Metered Automatic Transfer Switch PDU, 2 IEC309 32A Blue Inputs, 16 C13, 2 C19 Outlets, 2U, TAA
Offer details
Related Products
Description
The PDUMH32HVAT 7.7kW Single-Phase 200-240V Local Metered Automatic Transfer Switch / ATS PDU provides power monitoring and enables redundant power for network devices with non-redundant power supply configurations. Ideal for data centers and server rooms, it mounts in 2U of space in EIA-standard 19-inch racks and features 18 outlets (16 C13 and two C19) in two load banks, each bank protected by a 20A circuit breaker.
Dual three-meter input cords with IEC 309 32A Blue (2P+E) plugs connect to separate primary and secondary single-phase 200-240V power sources. The PDU constantly evaluates the power quality of both input sources. Dynamic solid-state (TRIAC) automatic transfer switching allows the PDU to switch to the secondary source within 1–5 milliseconds should the primary source fail or become unstable to ensure your connected equipment operates without interruption.
Multifunction digital display with LED indicators reports output current, voltage and kW loading information.
Primary and Secondary Inputs for Power Redundancy
Provides power monitoring and enables redundant power for network devices with non-redundant power supply configurations
Dual 3m input cords with IEC 309 32A Blue (2P+E) plugs connect to separate primary and secondary single-phase power sources
Automatic Transfer Switching
Dynamic solid-state (TRIAC) automatic transfer switching
Switches to secondary power source if primary source fails or becomes unstable
1–5 ms transfer time ensures uninterrupted operation of connected equipment
Built-in processor monitors both sources and prevents switching if secondary source is unavailable or of lower quality than primary source
Multifunction Digital Display
Front-panel digital display with LED indicators reports output current, voltage and kW loading information
20A Circuit Breakers
Protect each of 2 single-phase output banks
Front-panel LED indicates when breaker has tripped
Cord Retention Sleeves
Set of Plug-lock output power cable retention sleeves prevent accidental disconnection of connected devices
Mounts Horizontally in 2U of Rack Space
Compatible with EIA-standard 19 in. 4-post racks and rack enclosures
TAA-Compliant
Compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases
Dual three-meter input cords with IEC 309 32A Blue (2P+E) plugs connect to separate primary and secondary single-phase 200-240V power sources. The PDU constantly evaluates the power quality of both input sources. Dynamic solid-state (TRIAC) automatic transfer switching allows the PDU to switch to the secondary source within 1–5 milliseconds should the primary source fail or become unstable to ensure your connected equipment operates without interruption.
Multifunction digital display with LED indicators reports output current, voltage and kW loading information.
Primary and Secondary Inputs for Power Redundancy
Provides power monitoring and enables redundant power for network devices with non-redundant power supply configurations
Dual 3m input cords with IEC 309 32A Blue (2P+E) plugs connect to separate primary and secondary single-phase power sources
Automatic Transfer Switching
Dynamic solid-state (TRIAC) automatic transfer switching
Switches to secondary power source if primary source fails or becomes unstable
1–5 ms transfer time ensures uninterrupted operation of connected equipment
Built-in processor monitors both sources and prevents switching if secondary source is unavailable or of lower quality than primary source
Multifunction Digital Display
Front-panel digital display with LED indicators reports output current, voltage and kW loading information
20A Circuit Breakers
Protect each of 2 single-phase output banks
Front-panel LED indicates when breaker has tripped
Cord Retention Sleeves
Set of Plug-lock output power cable retention sleeves prevent accidental disconnection of connected devices
Mounts Horizontally in 2U of Rack Space
Compatible with EIA-standard 19 in. 4-post racks and rack enclosures
TAA-Compliant
Compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases
Specifications
Design | |
---|---|
PDU types | Metered, Switched |
Mounting | Horizontal |
Display | LCD |
Product colour | Black |
Type | Single-phase |
Rack capacity | 2U |
Housing material | Metal |
Ports & interfaces | |
AC outlets quantity | 18 AC outlet(s) |
AC outlet types | C13 coupler, C19 coupler |
Power plug | IEC309 |
Features | |
Cable length | 3 m |
LED indicators | Yes |
Ergonomics | |
Cable length | 3 m |
LED indicators | Yes |
Display | LCD |
Power | |
Maximum power | 7700 W |
Nominal input voltage | 200-240 V |
Nominal output voltage | 200-240 V |
Maximum current | 32 A |
AC input frequency | 50 - 60 Hz |
Weight & dimensions | |
Dimensions (WxDxH) | 444 x 317 x 88 mm |
Weight | 6.21 kg |
Width | 444.5 mm |
Depth | 317.5 mm |
Height | 88.9 mm |
Package weight | 9.21 kg |
Package dimensions (WxDxH) | 424 x 490 x 196 mm |
Package width | 424.2 mm |
Package depth | 490.2 mm |
Package height | 195.6 mm |
Packaging data | |
Package weight | 9.21 kg |
Package dimensions (WxDxH) | 424 x 490 x 196 mm |
Package width | 424.2 mm |
Package depth | 490.2 mm |
Package height | 195.6 mm |
Packaging content | |
Manual | Yes |
Operational conditions | |
Storage temperature (T-T) | -15 - 50 °C |
Operating relative humidity (H-H) | 5 - 95% |
Technical details | |
Sustainability certificates | RoHS |
Master (outer) case GTIN (EAN/UPC) | 00037332186881 |
Logistics data | |
Master (outer) case width | 424.2 mm |
Master (outer) case length | 490.2 mm |
Master (outer) case height | 195.6 mm |
Master (outer) case gross weight | 9.21 kg |
Products per master (outer) case | 1 pc(s) |
Country of origin | Taiwan |