APC Smart-UPS uninterruptible power supply (UPS) Line-Interactive 1.5 kVA 1000 W 4 AC outlet(s)
- Brand: APC
- Category:
- SKU: SMT1500RMI2U
- EAN: 0731304284758 5054484339328 85 ...4339328 8592978000585 4053162301917 0011411239071 4054318497386 5711045845956 5054533339323more
Smart-UPS - 1000W/1500VA, 230V, 2U, RJ45, USB, black
Offer details
Retail Prices
Merchant | Product | Condition | Updated | Price |
---|---|---|---|---|
Novatech Ltd | APC Smart-UPS SMT1500RMI2U Line-interactive UPS - 1500 VA/1000 W - 2U Rack-mountable - 3 Hour Sealed Lead Acid - 7 Minute - 220 V AC - 230 V AC - 4 x IEC 60320 C13, | New | 8131 hours ago | £1,037.50 |
Description
Intuitive LCD interface
Provides clear and accurate information in multiple languages with the ability to configure the UPS locally with easy to use navigation keys.
Predictive replace battery date
Dynamically provides the month and year when battery replacement is recommended to aide in long term maintenance planning.
Audible alarms
Provide notification of changing flywheel conditions
InfraStruXure Central compatible
Enables centralized management via APC InfraStruXure® Central.
SmartSlot
Customize UPS capabilities with management cards.
Cold-start capable
Provides temporary battery power when the utility power is out.
Serial Connectivity
Use any Home Automation network to monitor and control the S20 through its RS-232 serial port. For information on how to communicate with the S20, see APC's Application Note #102. Crestron and AMX installers should visit their respective websites for information on how to integrate the S20 into those networks.
Resettable circuit breakers
Enables a quick recovery from overload events.
Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
Disconnected battery notification
Warns when a battery is not available to provide backup power.
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Automatic restart of loads after UPS shutdown
Automatically starts up the connected equipment upon the return of utility power.
Adjustable voltage-transfer points
Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.
Adjustable voltage sensitivity
Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.
Audible alarms
Provides notification of changing utility power and UPS conditions.
User-replaceable batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
USB connectivity
Provides management of the UPS via a USB port (not available on all models).
Serial Connectivity
Provides management of the UPS via a serial port.
Temperature-compensated battery charging
Prolongs battery life by regulating the charge voltage according to battery temperature.
Boost and Trim Automatic Voltage Regulation (AVR)
Gives higher application availability by correcting low and high voltage conditions without using the battery.
Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Power conditioning
Protects connected loads from surges, spikes, lightning, and other power disturbances.
Network manageable
Provides remote management of the UPS over the network.
Adjustable voltage sensitivity
Provides the ability to adapt the Power Conditioner for optimal performance in specific power environments or generator applications.
Predicitive failure notification
Provides early-warning fault analysis ensuring proactive component replacement.
Provides clear and accurate information in multiple languages with the ability to configure the UPS locally with easy to use navigation keys.
Predictive replace battery date
Dynamically provides the month and year when battery replacement is recommended to aide in long term maintenance planning.
Audible alarms
Provide notification of changing flywheel conditions
InfraStruXure Central compatible
Enables centralized management via APC InfraStruXure® Central.
SmartSlot
Customize UPS capabilities with management cards.
Cold-start capable
Provides temporary battery power when the utility power is out.
Serial Connectivity
Use any Home Automation network to monitor and control the S20 through its RS-232 serial port. For information on how to communicate with the S20, see APC's Application Note #102. Crestron and AMX installers should visit their respective websites for information on how to integrate the S20 into those networks.
Resettable circuit breakers
Enables a quick recovery from overload events.
Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
Disconnected battery notification
Warns when a battery is not available to provide backup power.
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Automatic restart of loads after UPS shutdown
Automatically starts up the connected equipment upon the return of utility power.
Adjustable voltage-transfer points
Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.
Adjustable voltage sensitivity
Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.
Audible alarms
Provides notification of changing utility power and UPS conditions.
User-replaceable batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
USB connectivity
Provides management of the UPS via a USB port (not available on all models).
Serial Connectivity
Provides management of the UPS via a serial port.
Temperature-compensated battery charging
Prolongs battery life by regulating the charge voltage according to battery temperature.
Boost and Trim Automatic Voltage Regulation (AVR)
Gives higher application availability by correcting low and high voltage conditions without using the battery.
Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Power conditioning
Protects connected loads from surges, spikes, lightning, and other power disturbances.
Network manageable
Provides remote management of the UPS over the network.
Adjustable voltage sensitivity
Provides the ability to adapt the Power Conditioner for optimal performance in specific power environments or generator applications.
Predicitive failure notification
Provides early-warning fault analysis ensuring proactive component replacement.
Specifications
Power | |
---|---|
Output power | 1000 W |
Input operation voltage (min) | 151 V |
Input operation voltage (max) | 302 V |
Output operation voltage (min) | 220 V |
Output operation voltage (max) | 240 V |
Surge energy rating | 459 J |
Efficiency | 98.6% |
Emergency Power Off (EPO) | O |
Output power capacity | 1.5 kVA |
Performance | |
UPS topology | Line-Interactive |
LED indicators | Status |
Surge protection | Yes |
Waveform | Sine |
Noise level | 46 dB |
Auto-restart | Yes |
Automatic Voltage Regulation (AVR) | Yes |
Audible alarm(s) | Yes |
Hold time (max) | 2 ms |
Features | |
UPS topology | Line-Interactive |
Output power | 1000 W |
Input operation voltage (min) | 151 V |
Input operation voltage (max) | 302 V |
Output operation voltage (min) | 220 V |
Output operation voltage (max) | 240 V |
Surge energy rating | 459 J |
Efficiency | 98.6% |
Surge protection | Yes |
Emergency Power Off (EPO) | O |
Waveform | Sine |
Noise level | 46 dB |
Auto-restart | Yes |
Automatic Voltage Regulation (AVR) | Yes |
Audible alarm(s) | Yes |
Output power capacity | 1.5 kVA |
Hold time (max) | 2 ms |
Input frequency | 50/60 Hz |
Ports & interfaces | |
AC outlets quantity | 4 AC outlet(s) |
AC outlet types | C13 coupler |
Power plug | C14 coupler |
Number of output IEC jumpers | 2 |
USB port | Yes |
Serial interface | Yes |
Serial interface type | RJ-45 |
SmartSlot | Yes |
Battery | |
Battery technology | Sealed Lead Acid (VRLA) |
Battery recharge time | 3 h |
Typical backup time at half load | 25.8 min |
Typical backup time at full load | 7.2 min |
Hot-swap battery | Yes |
Cold start | Yes |
Automatic battery test | Yes |
Battery life (max) | 6 year(s) |
Battery capacity | 432 VAh |
Design | |
Form factor | Rackmount |
LED indicators | Status |
Product colour | Black |
Certification | CE, CSA, EAC, EN/IEC 62040-1, EN/IEC 62040-2, RCM, TUV, VDE, REACH, PEP, EOLI |
Rack capacity | 2U |
Operational conditions | |
Operating temperature (T-T) | 0 - 40 °C |
Storage temperature (T-T) | -15 - 45 °C |
Operating relative humidity (H-H) | 0 - 95% |
Storage relative humidity (H-H) | 0 - 95% |
Operating altitude | 0 - 3000 m |
Non-operating altitude | 0 - 15000 m |
Technical details | |
Sustainability certificates | ENERGY STAR, Green Premium |
Compliance certificates | RoHS |
Weight & dimensions | |
Package width | 594 mm |
Package depth | 603 mm |
Package height | 251 mm |
Weight | 28.6 kg |
Width | 432 mm |
Package weight | 31.9 kg |
Height | 86 mm |
Depth | 457 mm |
Packaging data | |
Rack mount kit | Yes |
Quick installation guide | Yes |
Cables included | RS-232, USB cable |
Package width | 594 mm |
Package depth | 603 mm |
Package height | 251 mm |
Package weight | 31.9 kg |
Software CD | Yes |
Logistics data | |
Products per pallet | 8 pc(s) |
Harmonized System (HS) code | 85078000 |
Certificates | |
Certification | CE, CSA, EAC, EN/IEC 62040-1, EN/IEC 62040-2, RCM, TUV, VDE, REACH, PEP, EOLI |
Other features | |
Nominal output voltage | 230 V |
Nominal input voltage | 230 V |
Products per pallet | 8 pc(s) |
Packaging content | |
Rack mount kit | Yes |
Quick installation guide | Yes |
Cables included | RS-232, USB cable |
Software CD | Yes |