APC NetShelter Rack PDU Advanced, Metered, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 48 Outlets, IEC309

APC NetShelter Rack PDU Advanced, Metered, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 48 Outlets, IEC309

NetShelter Rack PDU Advanced, Metered, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 48 Outlets, IEC309

Trade Prices

Distributor Product SKU Stock Updated Price
CMS Distribution

netshelt rack PDU 17 3kw 3ph 415 v

427654 Register free see stock
EET

Netshelter Rack Pdu Advanced

APDU10350ME
Exertis IT

NetShelter Rack PDU Advanced Metered 17.3kW 3PH 415V 30A 530P6 48 Outlet

10389829
Ingram Micro

NETSHELTER RACK PDU ADVANCED

CF77945
TD Synnex UK

APC NetShelter Rack PDU Advanced - Power distribution unit (rack-mountable) - metered - AC 400/415 V - 17.3 kW - 17300 VA - 3-phase - Ethernet 10/100, Ethernet 10/100/1000 - input: IEC 60309 530P6 - output connectors: 48 (24 x IEC 60320 C13/C15/C19/C21, 2

View on InTouch open_in_new
8166901
Tech Data - Sweden

NetShelter Rack PDU Advanced - Kraftdistributionsenhet (kan monteras i rack) - uppmätt - AC 400/415 V - 17.3 kW - 17300 VA - 3-fas - Ethernet 10/100, Ethernet 10/100/1000 - ingång: IEC 60309 530P6 - utgångskontakter: 48 (24 x IEC 60320 C13/C15/C19/C21

8166901
Westcoast

RACK PDU ADVANCED METERED 3PHASE 22.

View on Webshop open_in_new
APDU10350ME

Description

APC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within server and/or networking racks. PDU level power metering via remote access and local display for power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparreled deployment flexibility. Maximum outlet density with 48 outlets in a 2.2 wide form factor. Outlets on the PDUs are color coded and/or labeled by breaker and input phase on 3 phase models to simplify deployment. Provides an alternating phase design whereby each of the 3 phases are organized into small outlet groups which alternate from top to bottom of the PDU to facilitate better power cord management and promote better load balancing. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an Network Management Card to continue functioning in the event of an AC power loss. No interruption in Network communication, sensors operation, and alarm traps. Live Swap Network Management Card (NMC) which can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event. Rated and approved to operate up to 60C (140F) at full load ensures reliability and availability even in today's high density deployments. Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center. A second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy. 1% metering accuracy for the peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Two environmental sensor ports allow for optional sensors (sold separately) to be connected. For data center deployments across multiple regions, these PDUs are both UL and CE rated providing one PDU that can be used globally to simplify and standardize deployment.

Specifications

Design
On/off switchYes
PDU typesMetered
MountingVertical
DisplayLCD
Product colourBlack
TypeThree-phase
Rack capacity0U
Form factorRackmount
Regulatory ApprovalsCE, CSA C22.2 No 62368-1, EN 62368-1, FCC part 15 subpart B, UKCA, UL 62368-1
Ports & interfaces
AC outlets quantity48 AC outlet(s)
AC outlet typesC13 coupler, C15 coupler, C19 coupler, C21 coupler
Power plugIEC 60309
Ethernet LAN (RJ-45) ports2
USB ports quantity1
Features
Cable length1.8 m
LED indicatorsActivity, Network, Power
Daisy chainYes
Surge protectionYes
Colour-coded outletsYes
Security algorithms128-bit AES, 192-bit AES, 256-bit AES, DES, MD5, SNMP, SNMPv2, SNMPv3
Password protectionYes
Compatible productsCompatible with most NetShelter SX enclosures and third-party racks
Reset buttonYes
Management features
MonitoringCurrent, Humidity, Power, Temperature, Voltage
Outlet controlLock-out, Recycle, Turn off, Turn on
Firmware upgradeable viaNetwork, USB
Firmware upgradeableYes
Ergonomics
Cable length1.8 m
LED indicatorsActivity, Network, Power
DisplayLCD
Compatible productsCompatible with most NetShelter SX enclosures and third-party racks
Power
Maximum power22000 W
Nominal input voltage400 V
Nominal output voltage230 V
Output voltage230 V
Power protection featuresOverload
Maximum current32 A
Maximum total current draw per phase32 A
Load capacity22100 VA
Surge protectionYes
AC input frequency50 - 60 Hz
Number of phases3
Certificates
Compliance certificatesRoHS
Operational conditions
Operating temperature (T-T)-5 - 60 °C
Storage temperature (T-T)-25 - 65 °C
Storage relative humidity (H-H)5 - 95%
Operating relative humidity (H-H)5 - 95%
Operating temperature (T-T)23 - 140 °F
Operating altitude0 - 3048 m
Non-operating altitude0 - 15240 m
Weight & dimensions
Weight8.4 kg
Width56 mm
Depth75 mm
Height1780 mm
Package weight11.4 kg
Package width262 mm
Package depth132 mm
Package height1980 mm
Packaging data
Package weight11.4 kg
Package width262 mm
Package depth132 mm
Package height1980 mm
Security
Security algorithms128-bit AES, 192-bit AES, 256-bit AES, DES, MD5, SNMP, SNMPv2, SNMPv3
Password protectionYes
Technical details
Total carbon footprint (kg of CO2e)13750.11
Compliance certificatesRoHS
Logistics data
Total carbon footprint (kg of CO2e)13750.11