APC AP8881 power distribution unit (PDU) 42 AC outlet(s) 0U Black

APC AP8881 power distribution unit (PDU) 42 AC outlet(s) 0U Black

Rack PDU 2G, Metered, ZeroU, 11kW, 230V, (36) C13 & (6) C19

Trade Prices

Distributor Product SKU Stock Updated Price
Comstor Rack PDU 2G Metered ZeroU 1kW 230V (36) C13 & (6) C19 AP8881 Register free see stock
EET Rack PDU 2G, Metered, ZeroU, 1 AP8881
Exertis IT Rack PDU 2G Metered ZeroU 11kW 230V (36) C13 & (6) C19 10009690
Ingram Micro RACK PDU 2G METERED ZEROU 2708427
TD Synnex UK Rack PDU 2G, Metered, ZeroU, 11kW, 230V, (36) C13 & (6) C19 2056715
Tech Data - Sweden Metered Rack PDU - Grenuttag (kan monteras i rack) - AC 400 V - 11 kW - Ethernet 10/100, RS-232 - utgångskontakter: 42 (power IEC 60320 C13, IEC 60320 C19) - 0U - svart - för P/N: SMX1000C, SMX1500RM2UC, SMX1500RM2UCNC, SMX750C, SMX750CNC, SRT5KRMXLW- 2056715

Description

APC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers. Users can access and configure Metered Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency.

Specifications

Design
PDU typesMetered
MountingVertical
Product colourBlack
CertificationCSA C22.2 No. 60950,IEC 60950,UL 60950-1,VDE RoHS, REACH
Rack capacity0U
Ports & interfaces
AC outlets quantity42 AC outlet(s)
AC outlet typesC13 coupler, C19 coupler
Power plugIEC309
Output connections36x IEC 320 C13 6x IEC 320 C19
Input connection typeIEC 309 16A 3P+N+PE, IEC 309 20A 3P+N+E
Features
Cable length1.83 m
CertificationCSA C22.2 No. 60950,IEC 60950,UL 60950-1,VDE RoHS, REACH
Management features
MonitoringCurrent, Power, Voltage
Ergonomics
Cable length1.83 m
Power
Maximum power11000 W
Nominal input voltage400 V
Nominal output voltage230 V
Maximum current16 A
Maximum total current draw per phase16 A
Maximum input current per phase16 A
Load capacity11040 VA
AC input frequency50 - 60 Hz
Weight & dimensions
Dimensions (WxDxH)56 x 44 x 1791 mm
Weight6.38 kg
Certificates
CertificationCSA C22.2 No. 60950,IEC 60950,UL 60950-1,VDE RoHS, REACH
Operational conditions
Operating temperature (T-T)5 - 45 °C
Storage temperature (T-T)-25 - 65 °C
Storage relative humidity (H-H)5 - 95%
Operating relative humidity (H-H)5 - 95%