APC AP7950B power distribution unit (PDU) 13 AC outlet(s) 0U Black

APC AP7950B power distribution unit (PDU) 13 AC outlet(s) 0U Black

230V, 10A, 200V, 208V, 230V, 47 - 63 Hz, IEC-320 C14, 3.05 m, 200-240VAC

Trade Prices

Distributor Product SKU Stock Updated Price
EET RACK PDU SWITCHED ZERO U AP7950B Register free see stock
Exertis IT Switched PDU 10A 0U C13x16 10149332
Ingram Micro RACK PDU SWITCHED ZERO U 270B825
TD Synnex UK APC Switched Rack PDU Zero U - Power distribution strip (rack-mountable) - AC 200/208/230 V - Ethernet 10/100 - input: IEC 60320 C14 - output connectors: 16 (power IEC 60320 C13) - 3.05 m cord - black - for P/N: SCL400RMJ1U, SCL500RMI1UC, SCL500RMI1UNC, S 4107611
Tech Data - Sweden Switched Rack PDU Zero U - Grenuttag (kan monteras i rack) - AC 200/208/230 V - Ethernet 10/100 - ingång: IEC 60320 C14 - utgångskontakter: 16 (power IEC 60320 C13) - 3.05 m sladd - svart - för P/N: SCL400RMJ1U, SCL500RMI1UC, SCL500RMI1UNC, SMTL750RMI 4107611
Westcoast RACK PDU SWITCHED ZERO U 10A 230V (1 AP7950B

Description

Flash Upgradeable

Quickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only)

Remote Management Capabilities

Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.


Load indicator LED

Indicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits.

Power Delays

Allows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly.

Local Current Monitoring Display

The aggregate current draw per rack PDU is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip. (Available on designated SKUs only)

Remote Individual Outlet Control

Remotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment).

Alarm Thresholds

Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems. (Note: Only available on units with the current monitoring capabilities. Please see SKU specifications for availability)

Network Management Capabilities

Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage rack PDUs from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.

Integrates with StruxureWare Data Center Expert

An IT-ready, scalable access monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network

Flash Upgradeable

Quickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only)

Specifications

Design
PDU typesMetered, Switched
MountingVertical
Product colourBlack
CertificationVDE, CE, EAC, EN55022, EN55024, AS/NZS CISPR 22
Rack capacity0U
Ports & interfaces
AC outlets quantity13 AC outlet(s)
Power plugC14 coupler
Output connectionsSixteen IEC 320 C13 outlets
Features
Cable length3.05 m
LED indicatorsYes
CertificationVDE, CE, EAC, EN55022, EN55024, AS/NZS CISPR 22
Management features
MonitoringCurrent, Power, Voltage
Outlet controlLock-out, Recycle, Turn off, Turn on
Ergonomics
Cable length3.05 m
LED indicatorsYes
Power
Maximum power2300 W
Nominal input voltage200-230 V
Nominal output voltage230 V
Maximum current10 A
Maximum total current draw per phase10 A
Maximum input current per phase10 A
Load capacity2300 VA
AC input frequency47/63 Hz
Weight & dimensions
Dimensions (WxDxH)55.6 x 43.9 x 1244.6 mm
Weight4.3 kg
Package weight5.2 kg
Package dimensions (WxDxH)152.4 x 127 x 2133.6 mm
Certificates
CertificationVDE, CE, EAC, EN55022, EN55024, AS/NZS CISPR 22
Packaging data
Package weight5.2 kg
Package dimensions (WxDxH)152.4 x 127 x 2133.6 mm
Operational conditions
Operating temperature (T-T)-5 - 45 °C
Storage temperature (T-T)-25 - 65 °C
Storage relative humidity (H-H)5 - 95%
Operating relative humidity (H-H)5 - 95%
Operating temperature (T-T)23 - 113 °F
Operating altitude0 - 4500 m
Non-operating altitude0 - 15000 m
Technical details
Sustainability certificatesRoHS